Precision X-ray is the leading provider of safe, high output X-Ray irradiators used in modern translational research.
Automated microscopy and Spatial Proteomics
Real-time, label free cell analysis
Nano and micro particle analysis
Accelerate to discover
Related topics
Theranostics: From Mice to Men and Back
Jun 25, 2024
Recorded webinar
Presenters: Prof. Dr. Ken Herrmann and Prof. Dr. Katharina Lückerath – Moderator: Hannah Notebaert
Orion 2024 AACR poster: 17-plex single-step stain and imaging of cell Lung Carcinoma
Jun 21, 2024
RareCyte Orion is a benchtop, high resolution, whole slide multimodal imaging instrument. A combination of quantitative...
Hypoxia in the Tumor Immune Microenvironment (TIME)
Jun 6, 2024
Thursday, 11 July 2024, 16:00 CET | 10:00 EST
Zaver M. Bhujwalla, PhD
...
X-RAD 320 for irradiation therapy during quantifying study for in vivo collagen reorganization
Jun 5, 2024
Quantifying in vivo collagen reorganization during immunotherapy in murine melanoma with second harmonic generation...
Use of MRI and microCT to evaluate gene therapy for the treatment of discogenic back pain
Jun 4, 2024
MRI images were obtained using the 9.4T Bruker BioSpec system, equipped with 40 mm 1H quadrature volume resonator, and...
Exosome-Mediated Delivery of Small Molecules, RNA & DNA for Development of Novel Cancer Therapeutics
Jun 3, 2024
Disha Moholkar of University of Louisville's Gupta Lab
Tuesday, June 11, 2024, 6:30 PM...
Emulate in vivo conditions – introduce shear flow to your experiments with BioFlux system
May 27, 2024
Most research is still conducted in vitro without the presence of flow. We use the BioFlux System to give you the...
High-frequency Ultrasound System For Preclinical Imaging
May 13, 2024
The Prospect T1 is an innovative high-frequency ultrasound system designed specifically for in vivo preclinical imaging...
Apr 4, 2024
Tumor irradiation
At E13 eggs were randomized into CT only (delivering 0.12 Gy, n = 6) and irradiated groups (Precision X-Ray, Inc. SmART+ small animal irradiator, n = 6). Eggs were scanned by cone beam CT with a 2 mm aluminum filter using the mouse soft tissue, high dose parameters at 40 kVp and 12 mA, producing 0.1 mm voxels for Monte Carlo treatment planning using the SmART-ATP software (v2.0.20201216). The ROIs were hand-drawn and interpolated to create a 3D volume of interest. The isocenter and collimation were set to minimize irradiation of the chick embryo using parallel-opposed pair of beams at 0 and 180 degrees, which were optimized using Monte Carlo simulations (100 million photon histories) which modeled the mean radiation dose delivered to the isocenter (D mean) and normal tissues. Radiation was delivered as a single 12 Gy fraction to the tumor using a circular collimator and a 0.3 mm Cu filter. After irradiation and/or CT imaging, eggs were placed back into the incubator for 24 h prior to PET imaging.
Related technologies: X-ray irradiation
Get more info
Brand profile
Precision X-ray is the leading provider of safe, high output X-Ray irradiators used in modern translational research.
More info at:
www.precisionxray.com